地暖分水器使用的四个使用技巧!
来源:http://cddyt.cn 日期:2019-06-19 发布人:admin
注意一、首次运行通热水步骤
Note 1. Steps for first operation of hot water
1、首先打开分水器供水总环路阀门,将热水温度逐步升高注入管道里循环。
1. First, open the general loop valve of water supply for water diverter, and gradually raise the temperature of hot water into the pipeline for circulation.
2、检查分水器接口有无异样,并逐步打开分水器各支路阀门。
2. Check whether there is any difference in the diverter interface, and gradually open the diverter branch valves.
3、如有分水器及管道渗漏现象应及时关闭供水总阀门并及时与开发商或地热公司进行联系。
3. If there is leakage of water divider and pipeline, the water supply main valve should be closed in time and contacted with the developer or geothermal company in time.
注意二、首次运行排气方法有说道
Note 2. The exhaust method for the first operation is stated.
地暖首次运行时,因管道里有压力与水阻容易产生气塞,造成供回水不循环、温度不相等,应当进行逐路排气。具体方法如下:
During the first operation of ground heating, air plug is easy to occur due to pressure and water resistance in the pipeline, resulting in non-circulation of water supply and return and unequal temperature, so exhaust should be carried out one by one. The specific methods are as follows:
1、关闭采暖的总回水阀门和各环路调节;
1. Close the total return water valve of heating and adjust the loops.
2、首先打开分水器上的一个调节阀;
2. Open a regulating valve on the water divider first.
3、再打开分水器回水杠上的排气阀放水排气,排净空气后再关上此阀门;
3. Open the exhaust valve on the return pole of the water divider to discharge water and exhaust air, and then close the valve after discharging clean air.
济南地暖
4、同时打开下一路阀门。
4. Open the next valve at the same time.
依此类推,每路空气都排净后再讲阀门打开,系统即正式运行。
By analogy, the system will be officially operated when the valves are opened after each passage of air is exhausted.
注意三、出水管不热应清洗过滤器
Attention 3. Wash the filter when the outlet pipe is not hot
每台分水器前均装有一个过滤器,当水里杂质过多时,要及时清理过滤器。过滤器中杂志过多时,会出现出水管不热、地热不热等现象,通常应一年清洗一次过滤器。具体方法如下:
Each water separator is equipped with a filter. When there is too much impurity in the water, the filter should be cleaned up in time. When there are too many magazines in the filter, the outlet pipe is not hot and the geothermal is not hot. Usually the filter should be cleaned once a year. The specific methods are as follows:
1、关闭分水器上所有阀门,用活扳手逆时针打开过滤器端盖;
1. Close all valves on the water divider and open the end cap of the filter counterclockwise with a live wrench.
2、取出过滤器进行清洗,清洗完毕后原样装上放回。
2. Take out the filter and clean it. After cleaning, put it back on the original sample.
注意四、供暖结束后将水全部放出
Pay attention to 4. Release all the water after heating
地热在每年供暖期结束后,应将地热网中的过滤管道水全部排放出来。
After the end of the annual heating period, all the filtered pipe water in the geothermal network should be discharged.
原因:锅炉管道水中含有很多黏泥、杂志、锈渣等微小颗粒,水质浑浊,而地热管网的内径很细,水中含有的钙、镁、盐等物质沉淀就会生成坚硬的水垢挂覆在地热管网的内壁上,折弯处更加严重,即使靠加压水流也是冲刷不掉的。
Reasons: Boiler pipe water contains many tiny particles such as slime, magazine, rust slag, etc. The water quality is turbid, and the inner diameter of geothermal pipe network is very fine. The precipitation of calcium, magnesium, salt and other substances in water will produce hard scale and hang on the inner wall of geothermal pipe network. The bending is more serious, even by pressure water flow, it can not be washed away.
这就是今天由济南地暖小编给大家介绍的纯干货的内容了,相信今天的内容能给大家带来一定的帮助,如果您对文章的内容还有不明白的地方,欢迎大家点击我们的官方网站留言讨论:http://cddyt.cn